13 June 1997
Source: http://www.hnd.usace.army.mil/techinfo/cegssgml/08318.sec (SGML format) See Guide Specifications for Military Construction: http://jya.com/cegs.htm ------------------------------------------------------------------------------ ************************************************************************** DEPARTMENT OF THE ARMY CEGS-08318 (March 1989) U.S. ARMY CORPS OF ENGINEERS -------------------------- Superseding CEGS-08318 (November 1986) GUIDE SPECIFICATION FOR MILITARY CONSTRUCTION Includes note relocation Special change (August 1995) Includes changes through Notice 3 (March 1994) Includes Text Adjustment change 1 (September 1991) Latest Notice change indicated by tokens ************************************************************************** SECTION 08318 SECURITY-VAULT DOOR 03/89 ************************************************************************** NOTE: This guide specification covers the requirements for vault door units meeting the protective storage criteria for classified materials. This guide specification is to be used in the preparation of project specifications in accordance with ER 1110-345-720. ************************************************************************** PART 1 GENERAL 1.1 REFERENCES ************************************************************************** NOTE: Issue (date) of references included in project specifications need not be more current than provided by the latest change (Notice) to this guide specification. ************************************************************************** The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by basic designation only. FEDERAL SPECIFICATIONS (FS) FS AA-D-00600 (Rev C) Door, Vault, Security 1.2 GENERAL REQUIREMENTS The vault door unit shall be a steel security-vault type door with frame, [day gate], and ramp type threshold, and shall be a standard product of a manufacturer specializing in this type of fabrication. 1.3 SUBMITTALS ************************************************************************** NOTE: Submittals must be limited to those necessary for adequate quality control. The importance of an item in the project should be one of the primary factors in determining if a submittal for the item should be required. Indicate submittal classification in the blank space using "GA" when the submittal requires Government approval or "FIO" when the submittal is for information only. ************************************************************************** Government approval is required for submittals with a "GA" designation; submittals having an "FIO" designation are for information only. The following shall be submitted in accordance with Section 01300 SUBMITTAL PROCEDURES: SD-01 Data Security Vault Door; [_____]. Manufacturer's catalog data including catalog cuts and brochures. The data shall show that the proposed vault door unit conforms with the requirements in FS AA-D-00600, and has been tested and approved by the General Services Administration (GSA). SD-13 Certificates Security Vault Door; [_____]. Certification shall state that vault-door units that do not bear the GSA label are constructed to Class 5 standards. 1.4 DELIVERY AND STORAGE Door and frame assemblies shall be delivered to the jobsite in a protective covering with the brand and name clearly marked thereon. Materials delivered to the jobsite shall be inspected for damage, and unloaded with a minimum of handling. Storage shall be in a dry location with adequate ventilation, free from dust, water, and other contaminants, and which permits easy access for inspection and handling. Door assemblies shall be stored off the floor on nonabsorptive strips or wood platforms. Doors and frames shall be handled carefully to prevent damage. Damaged items that cannot be restored to like-new condition shall be replaced. PART 2 PRODUCTS 2.1 VAULT DOOR AND FRAME ************************************************************************** NOTE: Select the appropriate Type and Style designation for the door, and delete inapplicable portions. Although FS AA-D-00600 covers both a Class 5 and a Class 6 door, only the Class 5 door is presently available. Both the Class 5 and Class 6 doors afford protection for 20 man-hours against surreptitious entry, 30 man-minutes against covert-entry, and 20 man-hours of radiological attack. In addition, the Class 5 door affords protection for 10 man-minutes against forced entry. Type: Select the appropriate door type or types, and delete those not applicable. "Right opening swing" means hinges to the right when viewed from outside the vault. Specify the optical device only when requested by the Using Agency. Style: Specify Style K unless Style H is requested by the Using Agency. The GSA labeled vault door is a single-leaf door, and provides a clear opening of 1015 mm (40 inches) wide and 1980 mm (78 inches) high. A double-leaf vault door is available with a clear opening of 2080 mm (82 inches) wide and 1980 mm (78 inches) high. Both single-leaf and double-leaf vault doors may be obtained to satisfy special size requirements. The double-leaf and special size units are built to Class 5 standards, but are not tested and labeled by GSA. When custom size doors are required, verify availability with door manufacturers, and verify the acceptability of unlabeled doors with the Using Agency. ************************************************************************** Design and construction of the door and frame assembly shall conform to FS AA-D-00600. The door shall be Class 5, Type [IR - right opening swing with optical device] [IL - left opening swing with optical device ] [IIR - right opening swing without optical device] [IIL - left opening swing without optical device], Style [H - hand change combination lock] [K - key change combination lock]. [The optical device shall permit observation from the [inside to the outside] [outside to the inside] of the vault.] 2.2 DAY GATE ************************************************************************** NOTE: The day gate is not covered by FS AA-D-00600. Specify the day gate only when specifically requested by the Using Agency. ************************************************************************** The day gate shall be the manufacturer's standard product designed for use with the vault door furnished, and shall provide access control [and visual security]. The gate shall be hinged on the same side as the vault door, shall swing into the vault, and shall have a locking device operable from outside by key and from inside by knob or handle. PART 3 EXECUTION 3.1 INSTALLATION ************************************************************************** NOTE: The door frame is a nongrout type and is adaptable to walls of 150, 200, 250, or 300 mm (6, 8, 10, or 12 inch) thickness with a 13 mm (1/2-inch) tolerance. Where required, the availability of frames to accommodate thicker walls should be verified with manufacturers. Construction and wall opening size requirements will vary between manufacturers. There is no need to detail the door or frame; however, the walls must be detailed as necessary to show reinforcing. Wall opening sizes should be shown as "approximate," with the final size to be as determined by the vault door manufacturer. ************************************************************************** The vault door assembly shall be installed in strict compliance with the printed instructions and drawings provided by the manufacturer. The day gate shall be installed in a manner that will not interfere with operation of the release handle on the inside of the vault door. After installation, the door, the locking mechanism, and the inner escape device shall be adjusted for proper operation. -- End of Section --
|
|
|
|